ELEKTON-CDU
Controller CDU-12
|
|
|
TECHNICAL SPECIFICATIONS | |
|
PARAMETER |
VALUE |
Rated capacity, l/hr |
1,5 |
3,8 |
6,0 |
Maximum capacity no less than, l/hr |
1,65 |
4,2 |
6,6 |
Minimum capacity, l/hr |
0,01 |
0,01 |
0,01 |
Pump chamber volume, cm3(±5%) |
1,57 |
4,02 |
6,28 |
Maximum allowable pressure in the discharge line, atm |
250 |
100 |
60 |
Dosed chemical type |
Scale, corrosion, paraffin inhibitors, incl. aromatic hydrocarbons, hydrate growth inhibitors |
Service tank volume, m3 |
0,5 |
Kinematic viscosity of dosed media, cSt, max |
800 |
Maximum density of dosed media, kg/m3 |
2000 |
Maximum chemical heating temperature, °С |
+80 |
Power of the supply tank electric heaters, kW |
1,04 |
Power consumption of the unit, kW, max |
2,0 |
Rated voltage in three-phase power circuit, V |
380±30 |
Rated power frequency, Hz |
50±1 |
Rated motor power, kW |
0,25 |
Pressure protection of the dosing pump |
Upper and lower thresholds |
Overall dimensions, mm, max, height x width x depth |
1800*1004*1000 |
Zero-reagent weight, kg, max |
335 |
Operating mode |
Continuous and cyclic, unmanned |
Operating conditions: |
|
|
-50...+60 |
- Relative humidity at +25°C, %, max
|
100 |
Climatic version as per IEC 60721-2-1 |
UXL1 |
Enclosure type |
NEMA3, NEMA4 |
Explosion and fire hazard category as per NPB 105-03 |
DN |
Housing fire resistance as per SNiP 21-01-03 |
IV |
|