Catalogue of equipment: Controller ELEKTON-09 for VSD ELEKTON-05
|
|

|
 |
 |
Purpose and application |  |
|
Controller ELEKTON-09 for switchboard ELEKTON-05 is intended for rotating speed variation, optimization of work and protection of generally marketed electric motors.
Functionally and constructively the controller is divided into 2 blocks: frequency converter control unit Elekton-09.2
and interface module Elekton-09.1.
Controller is a programmable device, it makes possible to control work process with changing settings, to store in memory events log, to obtain data as graphic or digital mode.
|
|
Controller ELEKTON-09.1 for VSD ELEKTON-05
Controller ELEKTON-09.2 for VSD ELEKTON-05
|
 |
 |
Functional capabilities |  |
|
Controller provides the folloving functions:
- regulation of the electric motor’s rotation speed from built-in control panel;
- switchboard’s autorestart after the shutdown troubleshooting service;
- smooth electric motor’s acceleration with preset rate;
- electric motor rotation directionreversal;
- programmable frequency correction bursts to provide automatic putting
the well into operating duty;
- electric motor gradual braking when voltage limit value increasing in dc link;
- automatic maintenance of the technological parameter value (pressure, temperature, level and so on)
from 2 of the 8 analog inputs;
- data communication via one port RS-232 and two ports RS-485, connection
to the telemechanics system for remote control and on-line control – start-up, shutdown,
setpoints change;
- operation under field decay conditions if speeds of rotation exceed rated;
- possibility to vary characteristic U/F (for different types of loading) without switchboard’s shutdown;
- writing operating parameters of the switchboard (mains voltage, current, output frequency and so on) into
controller memory and their fast view on the controller display directly;
- fixation in event log of the time of main supply switching off and on;
- setpoints changing registration in event log with indication of the data and time of
the parameter’s value changing before and after, as well as the way of changing – remotely or by operator;
- recording in event log the course inhibiting the switchboard start;
- recording into event log the date and time of setpoints changing with indication of
previous and new values;
- record into memory the meanings of the mains voltage values within adjustable periods,
if it doesn’t allow the switchboard switching on;
- showing on controller display the protection name, which caused the switching off, with indication of
remaining period of time (in minutes and seconds) before ESP motor switching off;
- automatic frequency changing up to preset value during preset period of time;
- 2 modes of wedging of ESP rotary unit:
1. specified number of blows by increased voltage with specified output current frequency,
in forward direction;
2. specified number of blows by increased voltage with specified output current frequency,
in different directions – «swinging».
- programming of analog inputs in any of 3 standards: 0-4 V, 0-10 V, 4-20 mA;
- password setting for exception of an unauthorized access of the switch- board programming, 8 users password indentification;
- possibility of frequency convertor`s operation in modes of pulse-width and 6-pulse modulations.
|
|

|
 |
 |
Specifications |  |
|
| Operation factors |
Controller |
| Display |
4 lines with 20 symbols |
| Temperature condition, °Ñ |
-60...+40 |
| Frequency variation range, Hz |
0,5...70±1 |
| Processor |
programmable processor |
| Dimensions, mm |
254x244x70 |
| Weight, kg |
2,5 |
|
|
Linkage cables (PC - Controller)
Controller
ELEKTON-04,08,09.1"> |
 |
 |
Features |  |
|
Protection capabilities:
- main supply temporary overvoltage protection;
- external and internal short-circuit current protection;
- programmable operation threshold of circuit voltage rise protection;
- programmable operation threshold of circuit voltage reduction protection;
- ESP asynchronous electric motors’ insulance reduction protection;
- transistor overheating or cooling air flow disappearance protection;
- overload current time-current protection;
- motor’s overheating time-current protection;
- underload protection.
 |
Controller's advantage: |  |
|
- reliable and steady to electric noise;
- up-to-date microprocessor is applied;
- reliable elemental base is applied;
- full galvanic isolation of power supply circuit;
- menu setpoints are grouped according to their functionalities;
- possibility to set up setpoints as default;
- informative enlargement of display by increasing displayed symbols – 4 lines of 20 symbols each;
- graphical display connection possibility;
- measuring of the mains voltage on the switchboard’s input allows to fix the reason
of undervoltage in dc link (trouble of input rectifier or power circuit’s voltage derating);
- trere is a possibility to create technologist’s individual menu;
- possible equipping of Elekton-09 controllers with a function of information read-out to the USB Flash drive.
| |

RANGE of PRODUCTS
|  |